PZ770 Miniature Pressure Sensor

Engineered and manufactured by PMC-STS  |  Release 10.80.0652.A — 2026.03

What is this AID AI Datasheet™?

This AID AI Datasheet™ is an interactive engineering companion to the official STS PZ770 PDF datasheet — running entirely in your browser, no login, no installation required. All specifications are sourced directly from the published PMC-STS datasheet (Release 10.80.0652.A). The PDF datasheet remains the authoritative contractual document.

01

Select Pressure Range

Use the Pressure Explorer to find the right range (15–6000 psi) and view all accuracy and error band data instantly.

02

Check Accuracy vs. Temperature

Visualize published total error band across all temperature windows for all six pressure ranges. Values shown are from the manufacturer’s datasheet.

03

Verify Safety Margins

Enter your operating pressure to compute engineering estimates of proof and burst safety margins, derived from the manufacturer’s published ratings.

04

Choose Output Interface

Compare 4–20 mA, 0.5–4.5 V, and mV/V outputs side-by-side with full wiring tables.

05

Explore Process Connections

Select from 11 process connection options and view the corresponding dimension drawing.

06

Generate Ordering Code

Use the Smart Configurator to build a valid PZ770 ordering code from your selections.

07

Check Weight Budget

Calculate total installed sensor mass for aerospace weight budget planning.

08

Ask the AI Assistant

Get instant answers to application, specification, or configuration questions from the embedded AI.

Key Specifications at a Glance — Source: PMC-STS Datasheet Release 10.80.0652.A
Pressure Range
15 – 6000 psi
Best Static Accuracy
±0.08% FS
Burst Pressure
>12,000 psi
Operating Temp
-40 to +150°C
Sampling Rate
575 Hz
Weight (M12)
48 g
Shock
100 g
Vibration
5 kHz @ 100 g
PZ770 Sensor

PZ770 — Shown with 3/8-24 UNF D38999 connector

PZ770 Key Specifications
Pressure Range0 … 6000 psi (0 … 414 bar)
Best Static Accuracy±0.08% FS (Range #2)
Output Options4–20 mA  |  0.5–4.5 VDC  |  mV/V
Proof Pressure3× FS (max 12,000 psi for Range #6)
Burst Pressure>12,000 psi (>850 bar)
Operating Temp (mA/V)-40 … +150°C
Compensated Temp Range-40 … +125°C
Sampling Rate (4–20 mA)575 Hz
Shock100 g (Mil-Std-810)
Vibration5 kHz Sine @ 100 g (Mil-Std-810 Curve L)
Weight — M12 connector48 g (1.7 oz)
Weight — D38999 connector61 g (2.1 oz)
Housing Material316L Stainless Steel
Process ConnectorSuper Duplex High-Strength Alloy Steel
ESD Contact / Air±4 kV / ±8 kV (IEC 61000-4-2)
Reverse PolarityProtected — all output types
Pressure Range Summary
Range #psi Rangebar RangeStatic Acc (mA/V)Static Acc (mV/V)SensitivityProof Press.
#10 … <600 … <4.1≤0.20% FS≤0.35% FS2.3 mV/V3× FS
#260 … <1454.1 … <10.3≤0.08% FS≤0.50% FS4.6 mV/V3× FS
#3145 … <36010.3 … <25≤0.10% FS≤0.45% FS4.7 mV/V3× FS
#4360 … <101525 … <70≤0.15% FS≤0.35% FS4.1 mV/V3× FS
#51015 … <232070 … <160≤0.15% FS≤0.30% FS7.0 mV/V3× FS
#62320 … 6000160 … 414≤0.20% FS≤0.30% FS11.0 mV/V3× FS (max 12 kpsi)
Pressure Range Explorer

Select a pressure range and output type to view complete specifications.

Accuracy & Temperature Visualizer

Maximum total error band vs. temperature window (mA/V output). Points represent published datasheet values; lines are linear interpolation between datasheet temperature windows for visualization only.

Legend: Range #1 (<60 psi) Range #2 (<145 psi) Range #3 (<360 psi) Range #4 (<1015 psi) Range #5 (<2320 psi) Range #6 (≤6000 psi)
Full Error Band Table (mA/V — Maximum Values)
Rangepsi0–70°C (typ/max)-25–100°C (typ/max)-40–125°C (typ/max)
#1<600.5 / 0.7%0.7 / 1.0%2.8 / 3.5%
#2<1450.4 / 0.6%0.5 / 0.8%1.6 / 2.4%
#3<3600.2 / 0.4%0.3 / 0.6%0.8 / 1.2%
#4<10150.2 / 0.4%0.3 / 0.6%0.7 / 1.1%
#5<23200.2 / 0.4%0.3 / 0.6%0.8 / 1.2%
#6≤60000.3 / 0.5%0.4 / 0.7%0.8 / 1.2%
Pressure Survival & Margin Calculator

Enter your operating pressure to compute engineering estimates of proof and burst safety margins, derived from the manufacturer’s published 3× FS proof rating and >12,000 psi burst rating.

Output Interface Selector

Click a card to compare output options in detail.

4–20 mA

Current Loop

Industry-standard 2-wire current loop for industrial and aerospace long-cable applications.

✓ Immune to cable resistance & EMI
✓ 575 Hz sampling rate
⚠ Requires 9–40 VDC supply
0.5–4.5 V

Voltage Output

3-wire voltage output for direct ADC interface in data acquisition systems.

✓ Easy ADC interface, >10 kΩ load
✓ 7–36 VDC supply range
⚠ Supply influence: 0.3%
mV/V

Ratiometric Bridge

4-wire Wheatstone bridge — lowest power, ratiometric for lab and test applications.

✓ Ratiometric — supply noise cancels
✓ 1–10 VDC supply
⚠ Requires instrumentation amplifier
Electrical Specifications
Electrical Specifications
Electrical Connections & Wiring
Connector Drawings
Electrical ConnectionsConnector Figures
Mechanical Dimensions
Overall Dimensions

Overall dimensions in inch [mm].

Dimension Summary
Body Diameter
Ø 0.83 in [21.0 mm]
Body Length
0.83 in [21.1 mm]
Hex Across Flats
0.66 in [16.8 mm]
D38999 Conn. Length
1.05 in [26.6 mm]
M12×1 Conn. Length
0.71 in [17.9 mm]
Souriau Conn. Length
0.65 in [16.6 mm]
Physical Specifications
ParameterSpecification
Housing Material316L Stainless Steel
Process Connector MaterialSuper Duplex High-Strength Alloy Steel
Weight — M12×11.7 oz [48 g]
Weight — D389992.1 oz [61 g]
Oil Fill OptionsAS100 | Halocarbon | PAO-4 Non-Silicone | Dowsil 510
Process Connection Explorer

Select a process connection to view its dimensional drawing.

EMC Immunity Qualifications

All qualification data reproduced from the manufacturer’s datasheet. Values indicate test levels achieved, not product certifications for any specific application.

Power Freq Magnetic Field

30 A/m

50/60 Hz — IEC 61000-4-8

RF Field (80 MHz–1 GHz)

10 V/m, 80% AM

IEC 61000-4-3

RF Field (1.4–6.0 GHz)

3 V/m, 80% AM

IEC 61000-4-3

ESD — Contact

±4 kV

IEC 61000-4-2

ESD — Air

±8 kV

IEC 61000-4-2
Mechanical Qualifications

Shock

100 g

Mil-Std-810

Vibration

5 kHz Sine @ 100 g

Mil-Std-810 Curve L
Temperature Operating Limits
Parameter4–20 mA0.5–4.5 VmV/V
Operating Temp Range-40 … +125°C-40 … +150°C-40 … +150°C
Compensated Temp-40 … +125°C (all types)
Oil Fill Compatibility

AS100

Standard (F1)

General purpose aerospace

PAO-4 Non-Silicone

Non-Silicone (F2)

Silicon-free environments

Dowsil 510

Silicone (F3)

Elevated temp stability

Halocarbon

Special (F4)

≤5800 psi only; ≥100°C not rated
Smart Product Configurator

Build a valid PZ770 ordering code. Derived from official ordering matrix (pp. 9–10).

① Pressure Type

② Pressure Range

③ Process Connection

④ Electrical Connection

⑤ Output Signal

⑥ Static Accuracy

⑦ Potting

⑧ Oil Fill

⑨ Oxygen Cleaning

Generated Ordering Code
PZ770-23AQ-G3A0-P0-F1C0
Aerospace Weight Budget Calculator

Calculate total installed sensor mass for aerospace weight budgets. Per-unit weights are manufacturer-published values; total is a calculated sum.

PZ770 AI Engineering Assistant

Ask engineering questions about the PZ770. Responses are guidance only — the manufacturer’s published datasheet remains the authoritative specification document.

🤖 PZ770 AI Assistant
Hello! I am the PZ770 AI Engineering Assistant, an interactive companion tool for the AID AI Datasheet™.

I can help with: pressure range selection, accuracy vs. temperature trade-offs, output type recommendations, process connection selection, and ordering code guidance.

⚠ Authoritative specifications remain the manufacturer’s published datasheet (Release 10.80.0652.A). This assistant provides engineering guidance only.